Runtime Updating Variables
Beginner Tutorials
Introducing GNU Radio Flowgraph Fundamentals
Creating and Modifying Python Blocks DSP Blocks
SDR Hardware |
This tutorial describes how to update variables while a flowgraph is running using QT GUI Widgets.
Please review the previous tutorial, Variables in Flowgraphs, for an introduction to variables. The next tutorial, Signal Data Types, discusses data types and representing complex and real signals in GNU Radio.
QT GUI Range
The GNU Radio block library comes with QT GUI widgets which allows interaction and modification to a flowgraph while running. The QT GUI Range creates a slider bar that can be used to update a variable.
Search for range in the block library:
Drag and drop the QT GUI Range block into the workspace:
The QT GUI Range works like a variable block. The default parameters for the QT GUI Range need to be set. Double-click on the QT GUI Range block to edit the properties. The QT GUI Range block will replace the frequency variable, so first change the Id field to frequency.
The Default Value is the value when the flowgraph starts. Set the Default Value to 0. The Start and Stop are the start and stop values of the slider. Enter -samp_rate/2 as the start value and samp_rate/2 as the stop value. The Step value is the resolution of the slider. In this example the Step is set to 100 Hz:
A message is displayed, ID "frequency" is not unique. This is because there is a variable and QT GUI Range both using the name frequency. This problem will be addressed shortly. Click OK to save the properties.
Right click on the variable block and select Disable, or press D on the keyboard:
The block is now ignored and the error is resolved.
Run the flowgraph by clicking the arrow or Play button:
The flowgraph starts with a frequency of 0, the default value entered into the QT GUI Range block:
The frequency parameter can then be updated by:
- Dragging the slider bar
- Entering a value
- Click up or down arrows (which moves by the Step size)
The frequency has been updated to -5000 which is reflected in the frequency spectrum plot.
QT GUI Chooser
The QT GUI Chooser creates a drop-down menu of options for a variable. Navigate the block library: Core, GUI Widgets, QT, and drag and drop QT GUI Chooser into the workspace.
Update the default parameters for the Chooser block. The Chooser creates a list of options to select from while the flowgraph is running. In this example three frequencies are used: 0, 1000 and -2000. Update the following properties in the Chooser block:
- Id: frequency
- Default Option: 0
- Option 0: 0
- Label 0: Frequency: 0
- Option 1: 1000
- Label 1: Frequency: 1000
- Option 2: -2000
- Label 2: Frequency: -2000
The Option field is the value of the variable, Label is a text description that is displayed in the drop-down menu.
Click OK to save the parameters. Running the flowgraph will select the default value, Frequency: 0 which is seen in the frequency spectrum as well as the drop-down box in the upper left hand corner:
The values are selected by clicking on the drop-down menu. Click on Frequency: 1000:
The frequency is updated as seen in the frequency spectrum:
The next tutorial, Signal Data Types, discusses data types and representing complex and real signals in GNU Radio.